Features:
1) High efficiency, low operation temperature .
2) Built-in EMI filter
3) 100% full load burn-in test
4) Protection: Overload, short circuit
5) Competitive price, high reliability
6) Output: 12V, 15V, 24V,36V, 48V
7) Input: 110/220VAC, change by switch
8) Storage temperature / humidity: 0 - 50° C / 100%, -10° C / 80%, 60° C / 60%, 20% - 90% RH
9) Dimensions: 215 x 115 x 50mm
10) CE, RoHS certified
MODEL | S-400-36 | ||||
OUTPUT | DC VOLTAGE | 36V | |||
RATED CURRENT | 11A | ||||
RATED POWER | 396W | ||||
RIPPLE&NOISE | 240mVp-p | ||||
VOLTAGE ADJ.RANGE | 32.4-39.6V | ||||
VOLTAGE TOLERANCE | ±1.0% | ||||
LINE REGULATION | ±0.5% | ||||
LOAD REGULATION | ±0.5% | ||||
SETUP,RISE TIME | 300ms,50ms/230VAC 800ms,50ms/115VAC at full load | ||||
HOLD UP TIME(TYP.) | 90ms/230VAC 12ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85-264VAC 120-370VDC | |||
FREQUENCY RANGE | 47-63HZ | ||||
EFFICIENCY(Typ.) | 83% | ||||
AC CURRENT(Typ.) | 5.6A/115V 2.8A/230VAC | ||||
INRUSH CURRENT | COLD START 25A/115VAC 50A/230V | ||||
LEAKAGE CURRENT | 3.5mA/240VAC | ||||
PROTECTION | OVERLOAD | 105-150% RATED OUTPUT POWER | |||
Protection type:Hiccup mode,recovers automatically after fault condition | |||||
OVER VOLTAGE | 115-135% RATED OUTPUT VOLTAGE | ||||
Protection type:Hiccup mode,recovers automatically after fault condition | |||||
ENVIRONMENT | WORKING TEMP | -10~+60°C | |||
WORKING HUMIDITY | 20-90%RH non-condesing | ||||
STORAGE TEMP,HUMIDITY | -20~+85°C,10-95%RH | ||||
TEMP.COEFFICIENT | ±0.03%°C(0-50°C) | ||||
VIBRATION | 10-500HZ | ||||
SAFETY&EMC | SAFETY STANDARD | CE RoHS | |||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1minute | ||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70%RH | ||||
EMI CONDUCTION&RADIATION | Design refer to GB4943,UL60950,EN60950 | ||||
EMC STANDARD | Design refer to GB9254,EN55022 Class A | ||||
DIMENSION | L215*W115*H50mm | ||||
PACKING | 1.2kg,16pcs/19.2kg |